W1 Cover switch
BLW1(3)-16/WD series transfer switches are two products specially developed by Bruder Electric for distribution grid cover type FTU
- Product Features
- Technical Parameter
- Electric Data
-
BLW series universal changeover switch is one of the series products launched by Bruder Electric Jiangyin Co., Ltd. to meet customers.
BLW series universal conversion switch is suitable for AC 50HZ~60HZ, voltage to 380V and below or DC 20V and below NC program control machine tool equipment and other electrical circuits used as medium gas control conversion and distribution equipment remote control, electrical measuring instrument conversion and servo motor, micro motor control. Can also be used for small capacity squirrel cage asynchronous motor control, at present, our company has 1, 2, 3, 4 series 10A, 16A, 20A and 63A four specifications to choose from, fully consider the requirements of users in all walks of life.
Product features:
BLW1(3)-16/WD series transfer switches are two products specially developed by Bruder Electric for distribution grid cover type FTU
◾Conventional heating current16A
◾Operating Angle45°、90°
◾Maximum number of contacts in the contact system5节
◾Product protection level up to IP67, meet the requirements of outdoor use
Note: The BLW1-16/WD series has a smaller structure, which greatly saves the internal space of the cover FTU, and is recommended for use. Various special handles can be customized according to customer requirements.Product size:
-
◾ The altitude does not exceed 2000 meters
◾ The ambient temperature is -40 ° C to +80 ° C
◾ The relative humidity of the air does not exceed 90%
◾ Installation category is Ⅲ
◾ The pollution level is level 3
-
Model BLW□-16 BLW□-20 Rated insulation voltageUi 690V 690V Conventional heating currentIth 16A 20A Power frequency withstand voltage for 1 minute 1890V 1890V Alternating current le AC-21 on-off resistive load 16A 20A AC-15 Controls the electromagnet load COSΦ=0.4 24V 16A 20A 48V 8A 13A 110V 5A 9A 220V 4.6A 5A 380V 2.6A 4A Dc working current le DC-21 on/off resistive load Series contacts 1 2 3 4 24 48 70 95 16A 20A 48 60 95 110 12A 15A voltage 110V 1.6A 2A 220V 0.8A 1A 440V 0.27A 0.4A DC-13 controls the electromagnet load T=300ms Series contacts 1 2 3 4 24 48 70 95 12A 20A 48 60 95 110 2A 6A voltage 24V 16A 20A 48V 8A 12A 110V 1A 1.6A 220V 0.45A 0.8A 440V 0.1A 0.2A AC-3 squirrel-cage asynchronous motor starts with three phases and three stages 380V 3KW 4KW AC-4 squirrel cage induction motor start, brake, reverse, point three phase three 1.2KW 3KW Alternating current life 300,000 times 300,000 times Direct current life 200,000 times 200,000 times Mechanical life (positioning type) 500,000 times 500,000 times